Quotations are hereby invited for the following: Electrical Equipment & Components: • 1 each x Allen Bradley Vacuum Contactor 1502-VC4DBDA-0 SER.D or equivalent. Specifications: Vacuum, optimized for IntelliVAC control 3 pole, electrically held contactor Voltage ratings. Maximum rated voltage: 7.2 kV. System voltages (V): 2400, 3300, 4160, 4800, 6600, 6900. Dielectric voltage withstand rating (for 60 seconds): 18.2 kV/20 kV (IEC). Basic Impulse Level (B.I.L.) withstand: 60 kV. Coil voltage: 110 VDC. Frequency rating: 50/60 Hz Current ratings. Continuous current rating: 400 A. Maximum interrupting current rating @ 2400V-7200V: 6000 A (RMS Sym A). Maximum interrupting MVA rating: @ 2400V: 25 MVA @ 5000V: 50 MVA @ 7200V: 75 MVA. Short circuit withstand at rated voltage: 55 kA peak. Short time current rating capability: @ 1 second: 6.0 kA @ 30 seconds: 2.4 kA. Chopping current (average RMS): 0.5 A. Make and break capability at rated voltage: 4.0 kA. Ambient temperature: 40°C Contactor coil data. Electro-mechanical relay controlled (Mechanical latch) @ Control voltage (VCTL): 120 VAC Coil voltage (VCL): 110 VDC. Close current in rush (ADC): 5.6. Pilot relay (CR1) pick-up voltage: 102. Minimum trip coil voltage (VAC): 84. Trip coil current (A): 6 Electro-mechanical relay controlled (Electrically held) @ Control voltage (VCTL): 120 VAC Coil voltage (VCL): 110 VDC. Close current in rush (ADC): 7.3. Economized holding current (ADC): 0.13. Minimum CR1 coil pick-up voltage (VAC): 102. CR1 Coil dropout voltage (VAC): 75 Electro-mechanical relay controlled (Mechanical latch) @ Control voltage (VCTL): 230 VAC Coil voltage (VCL): 210 VDC. Not Available at this Control Voltage Electro-mechanical relay controlled (Electrically held) @ Control voltage (VCTL): 230 VAC Coil voltage (VCL): 210 VDC. Close current in rush (ADC): 8.3. Economized holding current (ADC): 0.11. Minimum CR1 coil pick-up voltage (VAC): 190. CR1 Coil dropout voltage (VAC): 140 IntelliVAC and IntelliVAC Plus control (Electrically held & mechanical latch) @ Control voltage: 110 to 240 VAC or 110 to 250 VDC Coil voltage: VAC: V_CL = 2 XV_CTL (Max.) VDC: V_CL = V_CTL. Close current (ADC, 200 milliseconds): 4.3. Hold current (ADC): 0.48. Pick-up voltage: 95. Drop-out voltage: 75. Trip current (ADC, 200 milliseconds): 5.5. Trip voltage: 70 Operational characteristics. Mechanical life (operations): Electrically held: 2,500,000. Mechanical latch: 100,000. Electrical life (operations): 1,000,000. Switching frequency (operations per hour): Electrically held: 600. Mechanical latch: 150 Opening and closing times. Electromechanical (Relay). Controlled (@ 50 Hz or 60 Hz). Maximum closing time (120V AC): 160 ms. Maximum opening time (120V AC): 50 ms. Maximum opening time (120V AC): 160 ms IntelliVAC and IntelliVAC Plus Control. (Electrically Held & Mechanical Latch) (@120/240V AC). Maximum closing time (50-60 Hz): 100/70 ms. Maximum opening time (without delay, for 50-60 Hz): 60 ms General Standard altitude capability: -1000 to 5000m (3300 to 16,500 ft). Contactor weight: 21.8 kg (48 lb). Auxiliary contact rating: A600 Auxiliary contacts on the vacuum contactor (max.): 3 N.O and 3 N.C, • 2 each x MV IntelliVAC Contactor Control Module Allen-Bradley 1503VC-BMC4 SER_D or equivalent. Specifications: Must be compatible with Allen-Bradley Vacuum Contactor 1502-VC-4DBDDA-0. Rated Supply Voltage: AC: 110V-240V RMS, 50-60Hz. DC: 110V-250V. Supply Current: Idle 125mA Max. Inrush 25A Peak (No External Capacitor). Sealed 1.0A Max. External Capacitor 1. Negative, 2. Positive, Contactor Interface, 3. Coil 2, Com, 4. Coil 2, Trip Coil (Mech. Latch), 5. Coil 1 Com, 6. Coil 1, Close Coil, 7. Open Command +, 8. Open Command, 9. Close Command +, 10. Close Command, Command Voltages: 50v-250 V Dc 100v-240 V Ac, 11. Auxiliary Contact, 12. Auxiliary Contact. Delivery Date: 2023/12/29. Delivery To: Molteno 3 - Pump Station. Delivery Address: 01 Molteno Pump Station, Oranjezight. (Tender №90897830)

Country: South Africa
Language: EN
Number: 90897830
Publication date: 13-09-2023
Source:

Description

Full information on the tender is closed.
For further work with the site read the information below.

About us

Leading searching system of world tenders

  • Largest database of tenders and sources of procurement of the World
  • Free daily mailings according to Your settings
  • Winners information
  • Convenient display and downloading of information

Choose us

Getting Started

After site registration, this functions will be available to You

  • Subscription to free mailing list for your keyword phrases
  • Tenders announcements previews
  • Download summary information in Excel format
  • View information about tender winners, suppliers and customers

REGISTER

For using all functions of our site and view full information you need to register a commercial account

  • Selected period
  • Pay access in any of the possible ways

Get full access