Quotations are hereby invited for the following: Provision of service for slow route safety guards repairs. Scope of work: 1. Fabricate and replace safety guards of O02 and P01 conveyors: • O02 tail pulley area; • O02 drive station and whole area from drive until after counterweight bend pulleys; • P01 tail pulley area; • P01 counterweight bend pulleys area. - Guard dimensions: 3000x730, frame material: L50x50x6; - Three Inspection doors; • P01 Tripper car; • P01 drive station. 2. O02 drive station and whole area from drive until after counterweight bend pulleys: • The safety guards are covering about 42 metres of a distance (from drive station going towards the tail); • Modify the safety guards to be light in weight by reducing the size of the safety guards; - The guard original length of 2900mm to be changed to 1365mm long; - Fabricate and install extra support for additional safety guards; - Fabricate and replace missing/damaged/rusted supports; - Support: square tube 70x70x6; 1430mm in height; 3. Ensure all guards installed to protect against the pulleys have the inspection doors for bearings maintenance; 4. All guards shall have handles and be bolted; 5. The hanging brackets must be also installed as an extra mounting method to keep guards in place; 6. Bracing the walkway between O03 and O02 by installing supports under the gratings and replace grating clamps. (Tender №102604098)

Country: South Africa
Language: EN
Number: 102604098
Publication date: 10-04-2024
Source:

Description

Full information on the tender is closed.
For further work with the site read the information below.

About us

Leading searching system of world tenders

  • Largest database of tenders and sources of procurement of the World
  • Free daily mailings according to Your settings
  • Winners information
  • Convenient display and downloading of information

Choose us

Getting Started

After site registration, this functions will be available to You

  • Subscription to free mailing list for your keyword phrases
  • Tenders announcements previews
  • Download summary information in Excel format
  • View information about tender winners, suppliers and customers

REGISTER

For using all functions of our site and view full information you need to register a commercial account

  • Selected period
  • Pay access in any of the possible ways

Get full access

Other tenders for this period

Teflon Solid Rod Source: Indiamart

G - Ureditev območja križišča državne ceste R3-646/1195 od km 13.660 do km 13.850 z občinskimi cestami LC 138071 in LZ 139061 v naselju Ivančna Gorica Source: Direkcija Republike Slovenije za infrastrukturo

Аймгийн сургууль, цэцэрлэгүүдийн хатуу эдлэл худалдан авах Source: Төрийн худалдан авах ажиллагааны цахим систем

Tenders are hereby invited for the following: Repair drive wheel hub at the Durban Container Terminal. Scope: 1. Repair front right drive wheel hub x 1; 2. Repair front left drive wheel hub x 1; 3. Repair rear right drive wheel hub x 1; 4. Repair rear left drive wheel hub x 1. Location of Service: TPT DCT pier 2 straddles. Source: ONLINE TENDERS

Quotations are hereby invited for the provision of mechanical spares to TPT Port of Cape Town - Once off. Specifications: - Wire mesh, knitted, colour: silver, material: stainless steel x 03 each; - Thruster, electro-hydraulic, type: brake x 08 each; - Tensioner, 8-240.00538_CN80283891, Type: Auxiliary wire rope x 08 each; - Winch, type: service hoist, capacity: 5000kg x 03 each; - Wire rope, type: service hoist, material: steel x 260m. Delivery Date: 19/04/2024. Location: Cape Town. Please note that this quotation was published late. Source: ONLINE TENDERS

Quotations are hereby invited for the following: Provision of Mantakraft panel doors repairs for Transnet SOC Ltd at the Port of Richards Bay. Specifications: 1. Supply and install 20 x panel door isolators at the E-house: • The isolator must come with metal shaft 282mm; • Pad lockable and din rail mounting. 2. The contractor must supply 80 (24V) LED indicator lamp: • Supply 80 x panel door lamp; • Supply 80 x panel door switch; • All lamps must clear white. 3. Supply and install 100 x heavy-duty panel hinges and locking mechanism: • Each panel hinges must have four mounting holes and it must turn at an angle of 1800. Locks must turn at an angle of 900; • All hinges must have same size 9.5 x 40 x 40mm (304 stainless steel); • Locks must be protected against water and dust according to IP65 of EN 60529; • The lock must take square key (6 x 6mm) and the locking element must be 45mm long. 4. Supply and install 400m of panel door rubber (IP65): • The contractor must install the sealing rubber in all electrical enclosure. The sealing rubber must fit on a plate thickness of 4mm; • Rubber type: Capping Rubber; • Material: Poly, EPDM, PVC. 5. Supply and install 200 x control switch and 15 x 220v enclosure heaters: • Button must be 22mm in diameter and must be IP65; • Button must operate with 12 to 24v. 6. Panel labelling: • Engrave aluminum plate for all labelling; • They are 100 plate for 80 x 30mm, 50 for 100 x 50mm and 200 for 50 x 20mm; • Labelling must be adhered on panel by means of heavy-duty glue and riveted. Location of Service: RBC DBT. Name of Institution: TPT. Source: ONLINE TENDERS